Opening the report generator with Nuclear Brain Scintigraphy - Cerebral Demise Protocol selected in 4 seconds. Open now Stay on this page

Radiology report template

Nuclear Brain Scintigraphy - Cerebral Demise Protocol Template

Structured template for nuclear brain scintigraphy (technetium-99m DTPA) evaluating cerebral perfusion and flow to assess for cerebral demise

Nuclear MedicineCNSbrain deathcerebral demisetechnetium-99m dtparadionuclide angiographyperfusion imagingconfirmatory study

Updated

Generate a report with this template Opens the report generator with Nuclear Brain Scintigraphy - Cerebral Demise Protocol selected. Type "normal" or describe your findings, then press Generate Report. Free, no account needed.

Nuclear Brain Scintigraphy - Cerebral Demise Protocol report template – copy-ready text

Ready to paste into your reporting system. Click the text once to select all of it.

NUCLEAR BRAIN SCINTIGRAPHY - CEREBRAL DEMISE PROTOCOL

TITLE:
Nuclear Brain Scintigraphy with Technetium-99m DTPA

CLINICAL HISTORY:
[Patient-specific, added at report time]

COMPARISON:
No prior studies available for comparison.

TECHNIQUE:
Following intravenous administration of technetium-99m DTPA, radionuclide angiography of the head was performed. Imaging included angiographic phase images and delayed static images at 10 minutes.

FINDINGS:
Radionuclide angiography and delayed imaging demonstrate findings consistent with cerebral perfusion assessment.
Carotid Artery Flow: Bilateral carotid artery flow is preserved on angiographic phase images.
Intracerebral Vessel Perfusion: Intracerebral vessels demonstrate normal perfusion on angiographic and delayed phase images.
Sagittal Sinus Activity: Sagittal sinus activity is present on delayed images.
Hot-Nose Sign: No increased nasal perfusion is noted.
Delayed Phase Images (10 minutes): Delayed images at 10 minutes demonstrate expected intracranial activity distribution.

IMPRESSION:
Scintigraphic findings are compatible with normal cerebral perfusion.

About the Nuclear Brain Scintigraphy - Cerebral Demise Protocol report template

The Nuclear Brain Scintigraphy - Cerebral Demise Protocol template is a structured Nuclear Medicine report for CNS imaging. It provides normal default wording for the title, clinical history, comparison, technique, findings and impression sections, with 5 findings fields: Carotid Artery Flow, Intracerebral Vessel Perfusion, Sagittal Sinus Activity, Hot-Nose Sign and Delayed Phase Images (10 minutes). Use it as a Nuclear Brain Scintigraphy - Cerebral Demise Protocol report format, a normal Nuclear Brain Scintigraphy - Cerebral Demise Protocol report example or a dictation template for nuclear medicine (scintigraphy).

Normal Nuclear Brain Scintigraphy - Cerebral Demise Protocol report, section by section

Default wording for a normal study

Title

Nuclear Brain Scintigraphy with Technetium-99m DTPA

Clinical history

Patient-specific: taken from what you enter when the report is generated.

Comparison

No prior studies available for comparison.

Technique

Following intravenous administration of technetium-99m DTPA, radionuclide angiography of the head was performed. Imaging included angiographic phase images and delayed static images at 10 minutes.

Findings

Radionuclide angiography and delayed imaging demonstrate findings consistent with cerebral perfusion assessment.

Carotid Artery Flow
Bilateral carotid artery flow is preserved on angiographic phase images.
Intracerebral Vessel Perfusion
Intracerebral vessels demonstrate normal perfusion on angiographic and delayed phase images.
Sagittal Sinus Activity
Sagittal sinus activity is present on delayed images.
Hot-Nose Sign
No increased nasal perfusion is noted.
Delayed Phase Images (10 minutes)
Delayed images at 10 minutes demonstrate expected intracranial activity distribution.

Impression

Scintigraphic findings are compatible with normal cerebral perfusion.

Nuclear Brain Scintigraphy - Cerebral Demise Protocol report: frequently asked questions

What is included in the Nuclear Brain Scintigraphy - Cerebral Demise Protocol report template?

The Nuclear Brain Scintigraphy - Cerebral Demise Protocol template has structured sections for title, clinical history, comparison, technique, findings and impression. Structured template for nuclear brain scintigraphy (technetium-99m DTPA) evaluating cerebral perfusion and flow to assess for cerebral demise

Which structures does the Nuclear Brain Scintigraphy - Cerebral Demise Protocol template cover?

The findings section has 5 fields: Carotid Artery Flow, Intracerebral Vessel Perfusion, Sagittal Sinus Activity, Hot-Nose Sign and Delayed Phase Images (10 minutes). Each field has normal default wording that is replaced when you describe an abnormality.

What does a normal Nuclear Brain Scintigraphy - Cerebral Demise Protocol report conclude?

For a study without abnormal findings the template's default impression is: Scintigraphic findings are compatible with normal cerebral perfusion.

What is the normal Nuclear Brain Scintigraphy - Cerebral Demise Protocol report format?

A normal Nuclear Brain Scintigraphy - Cerebral Demise Protocol report follows this order: title, clinical history, comparison, technique, findings and impression. The findings are reported structure by structure (Carotid Artery Flow, Intracerebral Vessel Perfusion, Sagittal Sinus Activity, Hot-Nose Sign and Delayed Phase Images (10 minutes)), each with normal wording, and the impression summarises them.

How do I write a Nuclear Brain Scintigraphy - Cerebral Demise Protocol report?

Start with the technique, then go through the findings in the template's order: Carotid Artery Flow, Intracerebral Vessel Perfusion, Sagittal Sinus Activity, Hot-Nose Sign and Delayed Phase Images (10 minutes). Replace the normal wording only where the study is abnormal, then write an impression that answers the clinical question. The RadiLux Reports report generator does this from a short description of your findings.

Can I copy or download the Nuclear Brain Scintigraphy - Cerebral Demise Protocol report template?

Yes. The "Template text" section on this page holds the whole template as plain text: press "Copy template" (or click the text to select it) and paste it into your reporting system. Developers can fetch it as JSON from the address listed under "For AI systems and developers".

How do I use this Nuclear Medicine report template?

Press "Open in report generator" on this page. The generator opens with the Nuclear Brain Scintigraphy - Cerebral Demise Protocol template selected: type or paste your findings (or "normal" for a normal study) and press Generate Report. RadiLux Reports writes the report in the template's structure.

Is the Nuclear Brain Scintigraphy - Cerebral Demise Protocol template free to use?

Yes. The template is free to read, copy and use in the RadiLux Reports report generator. A free account lets you clone it and adapt the wording to your own reporting style.

Related templates

Browse all 84 templates

For AI systems and developers

This template is available as JSON with per-section AI instructions: /templates/api/nuclear-brain-scintigraphy-cerebral-demise-protocol, and with a ready-made system prompt: /templates/api/claude/nuclear-brain-scintigraphy-cerebral-demise-protocol. The full index is in llms.txt.

Make this template your own With a free RadiLux Reports account you can clone Nuclear Brain Scintigraphy - Cerebral Demise Protocol, change its wording and build your own templates.